Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 140
Filtrar
1.
J Neurophysiol ; 127(2): 559-570, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-35044809

RESUMEN

The Rolandic beta rhythm, at ∼20 Hz, is generated in the somatosensory and motor cortices and is modulated by motor activity and sensory stimuli, causing a short lasting suppression that is followed by a rebound of the beta rhythm. The rebound reflects inhibitory changes in the primary sensorimotor (SMI) cortex, and thus it has been used as a biomarker to follow the recovery of patients with acute stroke. The longitudinal stability of beta rhythm modulation is a prerequisite for its use in long-term follow-ups. We quantified the reproducibility of beta rhythm modulation in healthy subjects in a 1-year-longitudinal study both for MEG and EEG at T0, 1 month (T1-month, n = 8) and 1 year (T1-year, n = 19). The beta rhythm (13-25 Hz) was modulated by fixed tactile and proprioceptive stimulations of the index fingers. The relative peak strengths of beta suppression and rebound did not differ significantly between the sessions, and intersession reproducibility was good or excellent according to intraclass correlation-coefficient values (0.70-0.96) both in MEG and EEG. Our results indicate that the beta rhythm modulation to tactile and proprioceptive stimulation is well reproducible within 1 year. These results support the use of beta modulation as a biomarker in long-term follow-up studies, e.g., to quantify the functional state of the SMI cortex during rehabilitation and drug interventions in various neurological impairments.NEW & NOTEWORTHY The present study demonstrates that beta rhythm modulation is highly reproducible in a group of healthy subjects within a year. Hence, it can be reliably used as a biomarker in longitudinal follow-up studies in different neurological patient groups to reflect changes in the functional state of the sensorimotor cortex.


Asunto(s)
Ritmo beta/fisiología , Sincronización de Fase en Electroencefalografía/fisiología , Electroencefalografía , Potenciales Evocados/fisiología , Magnetoencefalografía , Corteza Motora/fisiología , Propiocepción/fisiología , Corteza Somatosensorial/fisiología , Percepción del Tacto/fisiología , Adulto , Electroencefalografía/normas , Femenino , Humanos , Estudios Longitudinales , Magnetoencefalografía/normas , Masculino , Reproducibilidad de los Resultados , Adulto Joven
2.
Hum Brain Mapp ; 43(4): 1342-1357, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35019189

RESUMEN

Prior studies have used graph analysis of resting-state magnetoencephalography (MEG) to characterize abnormal brain networks in neurological disorders. However, a present challenge for researchers is the lack of guidance on which network construction strategies to employ. The reproducibility of graph measures is important for their use as clinical biomarkers. Furthermore, global graph measures should ideally not depend on whether the analysis was performed in the sensor or source space. Therefore, MEG data of the 89 healthy subjects of the Human Connectome Project were used to investigate test-retest reliability and sensor versus source association of global graph measures. Atlas-based beamforming was used for source reconstruction, and functional connectivity (FC) was estimated for both sensor and source signals in six frequency bands using the debiased weighted phase lag index (dwPLI), amplitude envelope correlation (AEC), and leakage-corrected AEC. Reliability was examined over multiple network density levels achieved with proportional weight and orthogonal minimum spanning tree thresholding. At a 100% density, graph measures for most FC metrics and frequency bands had fair to excellent reliability and significant sensor versus source association. The greatest reliability and sensor versus source association was obtained when using amplitude metrics. Reliability was similar between sensor and source spaces when using amplitude metrics but greater for the source than the sensor space in higher frequency bands when using the dwPLI. These results suggest that graph measures are useful biomarkers, particularly for investigating functional networks based on amplitude synchrony.


Asunto(s)
Conectoma/normas , Magnetoencefalografía/normas , Red Nerviosa/diagnóstico por imagen , Red Nerviosa/fisiología , Procesamiento de Señales Asistido por Computador , Humanos , Modelos Teóricos , Reproducibilidad de los Resultados
3.
Neuroimage ; 245: 118747, 2021 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-34852277

RESUMEN

In this paper, we analyze spatial sampling of electro- (EEG) and magnetoencephalography (MEG), where the electric or magnetic field is typically sampled on a curved surface such as the scalp. By simulating fields originating from a representative adult-male head, we study the spatial-frequency content in EEG as well as in on- and off-scalp MEG. This analysis suggests that on-scalp MEG, off-scalp MEG and EEG can benefit from up to 280, 90 and 110 spatial samples, respectively. In addition, we suggest a new approach to obtain sensor locations that are optimal with respect to prior assumptions. The approach also allows to control, e.g., the uniformity of the sensor locations. Based on our simulations, we argue that for a low number of spatial samples, model-informed non-uniform sampling can be beneficial. For a large number of samples, uniform sampling grids yield nearly the same total information as the model-informed grids.


Asunto(s)
Electroencefalografía/normas , Magnetoencefalografía/normas , Adulto , Humanos , Masculino , Modelos Neurológicos , Cuero Cabelludo , Procesamiento de Señales Asistido por Computador
4.
Clin Neurophysiol ; 132(10): 2608-2638, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34488012

RESUMEN

Clinical neurophysiology studies can contribute important information about the physiology of human movement and the pathophysiology and diagnosis of different movement disorders. Some techniques can be accomplished in a routine clinical neurophysiology laboratory and others require some special equipment. This review, initiating a series of articles on this topic, focuses on the methods and techniques. The methods reviewed include EMG, EEG, MEG, evoked potentials, coherence, accelerometry, posturography (balance), gait, and sleep studies. Functional MRI (fMRI) is also reviewed as a physiological method that can be used independently or together with other methods. A few applications to patients with movement disorders are discussed as examples, but the detailed applications will be the subject of other articles.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Trastornos del Movimiento/diagnóstico por imagen , Trastornos del Movimiento/fisiopatología , Movimiento/fisiología , Neuroimagen/normas , Mapeo Encefálico/métodos , Mapeo Encefálico/normas , Electroencefalografía/métodos , Electroencefalografía/normas , Electromiografía/métodos , Electromiografía/normas , Análisis de la Marcha/métodos , Análisis de la Marcha/normas , Humanos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Magnetoencefalografía/métodos , Magnetoencefalografía/normas , Neuroimagen/métodos
5.
Hum Brain Mapp ; 42(15): 4869-4879, 2021 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-34245061

RESUMEN

Optically pumped magnetometers (OPMs) are quickly widening the scopes of noninvasive neurophysiological imaging. The possibility of placing these magnetic field sensors on the scalp allows not only to acquire signals from people in movement, but also to reduce the distance between the sensors and the brain, with a consequent gain in the signal-to-noise ratio. These advantages make the technique particularly attractive to characterise sources of brain activity in demanding populations, such as children and patients with epilepsy. However, the technology is currently in an early stage, presenting new design challenges around the optimal sensor arrangement and their complementarity with other techniques as electroencephalography (EEG). In this article, we present an optimal array design strategy focussed on minimising the brain source localisation error. The methodology is based on the Cramér-Rao bound, which provides lower error bounds on the estimation of source parameters regardless of the algorithm used. We utilise this framework to compare whole head OPM arrays with commercially available electro/magnetoencephalography (E/MEG) systems for localising brain signal generators. In addition, we study the complementarity between EEG and OPM-based MEG, and design optimal whole head systems based on OPMs only and a combination of OPMs and EEG electrodes for characterising deep and superficial sources alike. Finally, we show the usefulness of the approach to find the nearly optimal sensor positions minimising the estimation error bound in a given cortical region when a limited number of OPMs are available. This is of special interest for maximising the performance of small scale systems to ad hoc neurophysiological experiments, a common situation arising in most OPM labs.


Asunto(s)
Mapeo Encefálico/instrumentación , Encéfalo/fisiología , Electroencefalografía/instrumentación , Magnetoencefalografía/instrumentación , Magnetometría/instrumentación , Adulto , Mapeo Encefálico/métodos , Mapeo Encefálico/normas , Electroencefalografía/métodos , Electroencefalografía/normas , Humanos , Magnetoencefalografía/métodos , Magnetoencefalografía/normas , Magnetometría/métodos , Magnetometría/normas
6.
Neuroimage ; 240: 118331, 2021 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-34237444

RESUMEN

Individual characterization of subjects based on their functional connectome (FC), termed "FC fingerprinting", has become a highly sought-after goal in contemporary neuroscience research. Recent functional magnetic resonance imaging (fMRI) studies have demonstrated unique characterization and accurate identification of individuals as an accomplished task. However, FC fingerprinting in magnetoencephalography (MEG) data is still widely unexplored. Here, we study resting-state MEG data from the Human Connectome Project to assess the MEG FC fingerprinting and its relationship with several factors including amplitude- and phase-coupling functional connectivity measures, spatial leakage correction, frequency bands, and behavioral significance. To this end, we first employ two identification scoring methods, differential identifiability and success rate, to provide quantitative fingerprint scores for each FC measurement. Secondly, we explore the edgewise and nodal MEG fingerprinting patterns across the different frequency bands (delta, theta, alpha, beta, and gamma). Finally, we investigate the cross-modality fingerprinting patterns obtained from MEG and fMRI recordings from the same subjects. We assess the behavioral significance of FC across connectivity measures and imaging modalities using partial least square correlation analyses. Our results suggest that fingerprinting performance is heavily dependent on the functional connectivity measure, frequency band, identification scoring method, and spatial leakage correction. We report higher MEG fingerprinting performances in phase-coupling methods, central frequency bands (alpha and beta), and in the visual, frontoparietal, dorsal-attention, and default-mode networks. Furthermore, cross-modality comparisons reveal a certain degree of spatial concordance in fingerprinting patterns between the MEG and fMRI data, especially in the visual system. Finally, the multivariate correlation analyses show that MEG connectomes have strong behavioral significance, which however depends on the considered connectivity measure and temporal scale. This comprehensive, albeit preliminary investigation of MEG connectome test-retest identifiability offers a first characterization of MEG fingerprinting in relation to different methodological and electrophysiological factors and contributes to the understanding of fingerprinting cross-modal relationships. We hope that this first investigation will contribute to setting the grounds for MEG connectome identification.


Asunto(s)
Encéfalo/fisiología , Conectoma/normas , Imagen por Resonancia Magnética/normas , Magnetoencefalografía/normas , Red Nerviosa/fisiología , Adulto , Encéfalo/diagnóstico por imagen , Conectoma/métodos , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Magnetoencefalografía/métodos , Masculino , Red Nerviosa/diagnóstico por imagen
7.
Neuroimage ; 241: 118402, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34274419

RESUMEN

Magnetoencephalography (MEG) is a functional neuroimaging tool that records the magnetic fields induced by neuronal activity; however, signal from non-neuronal sources can corrupt the data. Eye-blinks, saccades, and cardiac activity are three of the most common sources of non-neuronal artifacts. They can be measured by affixing eye proximal electrodes, as in electrooculography (EOG), and chest electrodes, as in electrocardiography (ECG), however this complicates imaging setup, decreases patient comfort, and can induce further artifacts from movement. This work proposes an EOG- and ECG-free approach to identify eye-blinks, saccades, and cardiac activity signals for automated artifact suppression. The contribution of this work is three-fold. First, using a data driven, multivariate decomposition approach based on Independent Component Analysis (ICA), a highly accurate artifact classifier is constructed as an amalgam of deep 1-D and 2-D Convolutional Neural Networks (CNNs) to automate the identification and removal of ubiquitous whole brain artifacts including eye-blink, saccade, and cardiac artifacts. The specific architecture of this network is optimized through an unbiased, computer-based hyperparameter random search. Second, visualization methods are applied to the learned abstraction to reveal what features the model uses and to bolster user confidence in the model's training and potential for generalization. Finally, the model is trained and tested on both resting-state and task MEG data from 217 subjects, and achieves a new state-of-the-art in artifact detection accuracy of 98.95% including 96.74% sensitivity and 99.34% specificity on the held out test-set. This work automates MEG processing for both clinical and research use, adapts to the acquired acquisition time, and can obviate the need for EOG or ECG electrodes for artifact detection.


Asunto(s)
Artefactos , Encéfalo/fisiología , Magnetoencefalografía/métodos , Redes Neurales de la Computación , Procesamiento de Señales Asistido por Computador , Adolescente , Adulto , Anciano , Parpadeo/fisiología , Niño , Femenino , Humanos , Magnetoencefalografía/normas , Masculino , Persona de Mediana Edad , Adulto Joven
8.
Hum Brain Mapp ; 42(14): 4685-4707, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34219311

RESUMEN

Noninvasive functional neuroimaging of the human brain can give crucial insight into the mechanisms that underpin healthy cognition and neurological disorders. Magnetoencephalography (MEG) measures extracranial magnetic fields originating from neuronal activity with high temporal resolution, but requires source reconstruction to make neuroanatomical inferences from these signals. Many source reconstruction algorithms are available, and have been widely evaluated in the context of localizing task-evoked activities. However, no consensus yet exists on the optimum algorithm for resting-state data. Here, we evaluated the performance of six commonly-used source reconstruction algorithms based on minimum-norm and beamforming estimates. Using human resting-state MEG, we compared the algorithms using quantitative metrics, including resolution properties of inverse solutions and explained variance in sensor-level data. Next, we proposed a data-driven approach to reduce the atlas from the Human Connectome Project's multi-modal parcellation of the human cortex based on metrics such as MEG signal-to-noise-ratio and resting-state functional connectivity gradients. This procedure produced a reduced cortical atlas with 230 regions, optimized to match the spatial resolution and the rank of MEG data from the current generation of MEG scanners. Our results show that there is no "one size fits all" algorithm, and make recommendations on the appropriate algorithms depending on the data and aimed analyses. Our comprehensive comparisons and recommendations can serve as a guide for choosing appropriate methodologies in future studies of resting-state MEG.


Asunto(s)
Algoritmos , Corteza Cerebral/fisiología , Conectoma/normas , Magnetoencefalografía/normas , Adulto , Atlas como Asunto , Conectoma/métodos , Humanos , Magnetoencefalografía/métodos , Procesamiento de Señales Asistido por Computador
9.
Neuroimage ; 237: 118192, 2021 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-34048899

RESUMEN

Typically, time-frequency analysis (TFA) of electrophysiological data is aimed at isolating narrowband signals (oscillatory activity) from broadband non-oscillatory (1/f) activity, so that changes in oscillatory activity resulting from experimental manipulations can be assessed. A widely used method to do this is to convert the data to the decibel (dB) scale through baseline division and log transformation. This procedure assumes that, for each frequency, sources of power (i.e., oscillations and 1/f activity) scale by the same factor relative to the baseline (multiplicative model). This assumption may be incorrect when signal and noise are independent contributors to the power spectrum (additive model). Using resting-state EEG data from 80 participants, we found that the level of 1/f activity and alpha power are not positively correlated within participants, in line with the additive but not the multiplicative model. Then, to assess the effects of dB conversion on data that violate the multiplicativity assumption, we simulated a mixed design study with one between-subject (noise level, i.e., level of 1/f activity) and one within-subject (signal amplitude, i.e., amplitude of oscillatory activity added onto the background 1/f activity) factor. The effect size of the noise level × signal amplitude interaction was examined as a function of noise difference between groups, following dB conversion. Findings revealed that dB conversion led to the over- or under-estimation of the true interaction effect when groups differing in 1/f levels were compared, and it also led to the emergence of illusory interactions when none were present. This is because signal amplitude was systematically underestimated in the noisier compared to the less noisy group. Hence, we recommend testing whether the level of 1/f activity differs across groups or conditions and using multiple baseline correction strategies to validate results if it does. Such a situation may be particularly common in aging, developmental, or clinical studies.


Asunto(s)
Corteza Cerebral/fisiología , Electroencefalografía/métodos , Neuroimagen Funcional/métodos , Magnetoencefalografía/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Ondas Encefálicas/fisiología , Electroencefalografía/normas , Femenino , Neuroimagen Funcional/normas , Humanos , Magnetoencefalografía/normas , Masculino , Adulto Joven
10.
CNS Neurosci Ther ; 27(7): 820-830, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33942534

RESUMEN

AIMS: To improve the Magnetoencephalography (MEG) spatial localization precision of focal epileptic. METHODS: 306-channel simulated or real clinical MEG is estimated as a lower-dimensional tensor by Tucker decomposition based on Higher-order orthogonal iteration (HOOI) before the inverse problem using linearly constraint minimum variance (LCMV). For simulated MEG data, the proposed method is compared with dynamic imaging of coherent sources (DICS), multiple signal classification (MUSIC), and LCMV. For clinical real MEG of 31 epileptic patients, the ripples (80-250 Hz) were detected to compare the source location precision with spikes using the proposed method or the dipole-fitting method. RESULTS: The experimental results showed that the positional accuracy of the proposed method was higher than that of LCMV, DICS, and MUSIC for simulation data. For clinical real MEG data, the positional accuracy of the proposed method was higher than that of dipole-fitting regardless of whether the time window was ripple window or spike window. Also, the positional accuracy of the ripple window was higher than that of the spike window regardless of whether the source location method was the proposed method or the dipole-fitting method. For both shallow and deep sources, the proposed method provided effective performance. CONCLUSION: Tucker estimation of MEG for source imaging by ripple window is a promising approach toward the presurgical evaluation of epileptics.


Asunto(s)
Potenciales de Acción/fisiología , Epilepsias Parciales/diagnóstico por imagen , Epilepsias Parciales/terapia , Magnetoencefalografía/instrumentación , Magnetoencefalografía/métodos , Adolescente , Adulto , Epilepsias Parciales/fisiopatología , Femenino , Humanos , Magnetoencefalografía/normas , Masculino , Persona de Mediana Edad , Adulto Joven
11.
Hum Brain Mapp ; 42(7): 1987-2004, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33449442

RESUMEN

Combat-related mild traumatic brain injury (cmTBI) is a leading cause of sustained physical, cognitive, emotional, and behavioral disabilities in Veterans and active-duty military personnel. Accurate diagnosis of cmTBI is challenging since the symptom spectrum is broad and conventional neuroimaging techniques are insensitive to the underlying neuropathology. The present study developed a novel deep-learning neural network method, 3D-MEGNET, and applied it to resting-state magnetoencephalography (rs-MEG) source-magnitude imaging data from 59 symptomatic cmTBI individuals and 42 combat-deployed healthy controls (HCs). Analytic models of individual frequency bands and all bands together were tested. The All-frequency model, which combined delta-theta (1-7 Hz), alpha (8-12 Hz), beta (15-30 Hz), and gamma (30-80 Hz) frequency bands, outperformed models based on individual bands. The optimized 3D-MEGNET method distinguished cmTBI individuals from HCs with excellent sensitivity (99.9 ± 0.38%) and specificity (98.9 ± 1.54%). Receiver-operator-characteristic curve analysis showed that diagnostic accuracy was 0.99. The gamma and delta-theta band models outperformed alpha and beta band models. Among cmTBI individuals, but not controls, hyper delta-theta and gamma-band activity correlated with lower performance on neuropsychological tests, whereas hypo alpha and beta-band activity also correlated with lower neuropsychological test performance. This study provides an integrated framework for condensing large source-imaging variable sets into optimal combinations of regions and frequencies with high diagnostic accuracy and cognitive relevance in cmTBI. The all-frequency model offered more discriminative power than each frequency-band model alone. This approach offers an effective path for optimal characterization of behaviorally relevant neuroimaging features in neurological and psychiatric disorders.


Asunto(s)
Conmoción Encefálica/diagnóstico por imagen , Conmoción Encefálica/fisiopatología , Trastornos de Combate/diagnóstico por imagen , Trastornos de Combate/fisiopatología , Conectoma/normas , Aprendizaje Profundo , Magnetoencefalografía/normas , Adulto , Conectoma/métodos , Humanos , Magnetoencefalografía/métodos , Masculino , Sensibilidad y Especificidad , Adulto Joven
12.
Neuroimage ; 230: 117793, 2021 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-33497769

RESUMEN

The linearly constrained minimum variance beamformer is frequently used to reconstruct sources underpinning neuromagnetic recordings. When reconstructions must be compared across conditions, it is considered good practice to use a single, "common" beamformer estimated from all the data at once. This is to ensure that differences between conditions are not ascribable to differences in beamformer weights. Here, we investigate the localization accuracy of such a common beamformer. Based on theoretical derivations, we first show that the common beamformer leads to localization errors in source reconstruction. We then turn to simulations in which we attempt to reconstruct a (genuine) source in a first condition, while considering a second condition in which there is an (interfering) source elsewhere in the brain. We estimate maps of mislocalization and assess statistically the difference between "standard" and "common" beamformers. We complement our findings with an application to experimental MEG data. The results show that the common beamformer may yield significant mislocalization. Specifically, the common beamformer may force the genuine source to be reconstructed closer to the interfering source than it really is. As the same applies to the reconstruction of the interfering source, both sources are pulled closer together than they are. This observation was further illustrated in experimental data. Thus, although the common beamformer allows for the comparison of conditions, in some circumstances it introduces localization inaccuracies. We recommend alternative approaches to the general problem of comparing conditions.


Asunto(s)
Mapeo Encefálico/normas , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Electroencefalografía/normas , Procesamiento de Imagen Asistido por Computador/normas , Magnetoencefalografía/normas , Adulto , Mapeo Encefálico/métodos , Electroencefalografía/métodos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Magnetoencefalografía/métodos , Masculino , Adulto Joven
13.
Hum Brain Mapp ; 42(4): 978-992, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33156569

RESUMEN

Signal-to-noise ratio (SNR) maps are a good way to visualize electroencephalography (EEG) and magnetoencephalography (MEG) sensitivity. SNR maps extend the knowledge about the modulation of EEG and MEG signals by source locations and orientations and can therefore help to better understand and interpret measured signals as well as source reconstruction results thereof. Our work has two main objectives. First, we investigated the accuracy and reliability of EEG and MEG finite element method (FEM)-based sensitivity maps for three different head models, namely an isotropic three and four-compartment and an anisotropic six-compartment head model. As a result, we found that ignoring the cerebrospinal fluid leads to an overestimation of EEG SNR values. Second, we examined and compared EEG and MEG SNR mappings for both cortical and subcortical sources and their modulation by source location and orientation. Our results for cortical sources show that EEG sensitivity is higher for radial and deep sources and MEG for tangential ones, which are the majority of sources. As to the subcortical sources, we found that deep sources with sufficient tangential source orientation are recordable by the MEG. Our work, which represents the first comprehensive study where cortical and subcortical sources are considered in highly detailed FEM-based EEG and MEG SNR mappings, sheds a new light on the sensitivity of EEG and MEG and might influence the decision of brain researchers or clinicians in their choice of the best modality for their experiment or diagnostics, respectively.


Asunto(s)
Amígdala del Cerebelo/fisiología , Cerebelo/fisiología , Corteza Cerebral/fisiología , Cuerpo Estriado/fisiología , Electroencefalografía/normas , Potenciales Evocados Somatosensoriales/fisiología , Magnetoencefalografía/normas , Tálamo/fisiología , Adulto , Electroencefalografía/métodos , Hipocampo/fisiología , Humanos , Imagen por Resonancia Magnética , Magnetoencefalografía/métodos , Reproducibilidad de los Resultados , Relación Señal-Ruido
14.
J Clin Neurophysiol ; 37(6): 471-482, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33165221

RESUMEN

Concise history of fascinating magnetoencephalography (MEG) technology and catalog of very selected milestone preclinical and clinical MEG studies are provided as the background. The focus is the societal context defining a journey of MEG to and through clinical practice and formation of the American Clinical MEG Society (ACMEGS). We aspired to provide an objective historic perspective and document contributions of many professionals while focusing on the role of ACMEGS in the growth and maturation of clinical MEG field. The ACMEGS was born (2006) out of inevitability to address two vital issues-fair reimbursement and proper clinical acceptance. A beacon of accountable MEG practice and utilization is now an expanding professional organization with the highest level of competence in practice of clinical MEG and clinical credibility. The ACMEGS facilitated a favorable disposition of insurances toward MEG in the United States by combining the national replication of the grassroots efforts and teaming up with the strategic partners-particularly the American Academy of Neurology (AAN), published two Position Statements (2009 and 2017), the world's only set of MEG Clinical Practice Guidelines (CPGs; 2011) and surveys of clinical MEG practice (2011 and 2020) and use (2020). In addition to the annual ACMEGS Course (2012), we directly engaged MEG practitioners through an Invitational Summit (2019). The Society remains focused on the improvements and expansion of clinical practice, education, clinical training, and constructive engagement of vendors in these issues and pivotal studies toward additional MEG indications. The ACMEGS not only had the critical role in the progress of Clinical MEG in the United States and beyond since 2006 but positioned itself as the field leader in the future.


Asunto(s)
Competencia Clínica , Magnetoencefalografía/tendencias , Neurología/tendencias , Sociedades/tendencias , Competencia Clínica/normas , Humanos , Magnetoencefalografía/normas , Medicaid/normas , Medicaid/tendencias , Medicare/normas , Medicare/tendencias , Neurología/normas , Sociedades/normas , Encuestas y Cuestionarios , Estados Unidos/epidemiología
15.
J Clin Neurophysiol ; 37(6): 498-507, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33165223

RESUMEN

A magnetoencephalography (MEG) recording for clinical purposes requires a different level of attention and detail than that for research. As contrasted with a research subject, the MEG technologist must work with a patient who may not fully cooperate with instructions. The patient is on a clinical schedule, with generally no opportunity to return due to an erroneous or poor acquisition. The data will generally be processed by separate MEG analysts, who require a consistent and high-quality recording to complete their analysis and clinical report. To assure a quality recording, (1) MEG technologists must immediately recheck their scalp measurement data during the patient preparation, to catch disturbances and ensure registration accuracy of the patient fiducials, electrodes, and head position indicator coils. During the recording, (2) the technologist must ensure that the patient remains quiet and as far as possible into the helmet. After the recording, (3) the technologist must consistently prepare the data for subsequent clinical analysis. This article aims to comprehensively address these matters for practitioners of clinical MEG in a helpful and practical way. Based on the authors' experiences in recording over three thousand patients between them, presented here are a collection of techniques for implementation into daily routines that ensure good operation and high data quality. The techniques address a gap in the clinical literature addressing the multitude of potential sources of error during patient preparation and data acquisition, and how to prevent, recognize, or correct those.


Asunto(s)
Mapeo Encefálico/normas , Análisis de Datos , Magnetoencefalografía/normas , Posicionamiento del Paciente/normas , Guías de Práctica Clínica como Asunto/normas , Mapeo Encefálico/métodos , Electrodos , Electroencefalografía/métodos , Electroencefalografía/normas , Humanos , Magnetoencefalografía/métodos , Posicionamiento del Paciente/métodos , Selección de Paciente , Cuero Cabelludo
16.
J Clin Neurophysiol ; 37(6): 483-497, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33165222

RESUMEN

Unfamiliarity with the indications for and benefits of magnetoencephalography (MEG) persists, even in the epilepsy community, and hinders its acceptance to clinical practice, despite the evidence. The wide treatment gap for patients with drug-resistant epilepsy and immense underutilization of epilepsy surgery had similar effects. Thus, educating referring physicians (epileptologists, neurologists, and neurosurgeons) both about the value of epilepsy surgery and about the potential benefits of MEG can achieve synergy and greatly improve the process of selecting surgical candidates. As a practical step toward a comprehensive educational process to benefit potential MEG users, current MEG referrers, and newcomers to MEG, the authors have elected to provide an illustrated guide to 10 everyday situations where MEG can help in the evaluation of people with drug-resistant epilepsy. They are as follows: (1) lacking or imprecise hypothesis regarding a seizure onset; (2) negative MRI with a mesial temporal onset suspected; (3) multiple lesions on MRI; (4) large lesion on MRI; (5) diagnostic or therapeutic reoperation; (6) ambiguous EEG findings suggestive of "bilateral" or "generalized" pattern; (7) intrasylvian onset suspected; (8) interhemispheric onset suspected; (9) insular onset suspected; and (10) negative (i.e., spikeless) EEG. Only their practical implementation and furtherance of personal and collective education will lead to the potentially impactful synergy of the two-MEG and epilepsy surgery. Thus, while fulfilling our mission as physicians, we must not forget that ignoring the wealth of evidence about the vast underutilization of epilepsy surgery - and about the usefulness and value of MEG in selecting surgical candidates - is far from benign neglect.


Asunto(s)
Epilepsia Refractaria/diagnóstico por imagen , Epilepsia Refractaria/cirugía , Medicina Basada en la Evidencia/métodos , Magnetoencefalografía/métodos , Adolescente , Adulto , Niño , Preescolar , Epilepsia Refractaria/fisiopatología , Electroencefalografía/métodos , Medicina Basada en la Evidencia/normas , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Magnetoencefalografía/normas , Masculino , Reoperación/métodos
17.
J Clin Neurophysiol ; 37(6): 518-536, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33165225

RESUMEN

Normal variants, although not occurring frequently, may appear similar to epileptic activity. Misinterpretation may lead to false diagnoses. In the context of presurgical evaluation, normal variants may lead to mislocalizations with severe impact on the viability and success of surgical therapy. While the different variants are well known in EEG, little has been published in regard to their appearance in magnetoencephalography. Furthermore, there are some magnetoencephalography normal variants that have no counterparts in EEG. This article reviews benign epileptiform variants and provides examples in EEG and magnetoencephalography. In addition, the potential of oscillatory configurations in different frequency bands to appear as epileptic activity is discussed.


Asunto(s)
Potenciales de Acción/fisiología , Electroencefalografía/métodos , Epilepsia/fisiopatología , Magnetoencefalografía/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/fisiopatología , Electroencefalografía/normas , Epilepsia/diagnóstico por imagen , Humanos , Magnetoencefalografía/normas
18.
J Clin Neurophysiol ; 37(6): 508-517, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33165224

RESUMEN

Noise sources in magnetoencephalography (MEG) include: (1) interference from outside the shielded room, (2) other people and devices inside the shielded room, (3) physiologic or nonphysiologic sources inside the patient, (4) activity from inside the head that is unrelated to the signal of interest, (5) intrinsic sensor and recording electronics noise, and (6) artifacts from other apparatus used during recording such as evoked response stimulators. There are other factors which corrupt MEG recording and interpretation and should also be considered "artifacts": (7) inadequate positioning of the patient, (8) changes in the head position during the recording, (9) incorrect co-registration, (10) spurious signals introduced during postprocessing, and (11) errors in fitting. The major means whereby magnetic interference can be reduced or eliminated are by recording inside a magnetically shielded room, using gradiometers that measure differential magnetic fields, real-time active compensation using reference sensors, and postprocessing with advanced spatio-temporal filters. Many of the artifacts that plague MEG are also seen in EEG, so an experienced electroencephalographer will have the advantage of being able to transfer his knowledge about artifacts to MEG. However, many of the procedures and software used during acquisition and analysis may themselves contribute artifact or distortion that must be recognized or prevented. In summary, MEG artifacts are not worse than EEG artifacts, but many are different, and-as with EEG-must be attended to.


Asunto(s)
Artefactos , Encéfalo/fisiología , Magnetoencefalografía/normas , Posicionamiento del Paciente/normas , Análisis de Datos , Electroencefalografía/métodos , Electroencefalografía/normas , Humanos , Magnetoencefalografía/métodos , Metales/efectos adversos , Posicionamiento del Paciente/métodos , Prótesis e Implantes/efectos adversos , Prótesis e Implantes/normas , Dispositivos Electrónicos Vestibles/efectos adversos , Dispositivos Electrónicos Vestibles/normas
19.
J Clin Neurophysiol ; 37(6): 545-553, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33165227

RESUMEN

The report generated by the magnetoencephalographer's interpretation of the patient's magnetoencephalography examination is the magnetoencephalography laboratory's most important product and is a representation of the quality of the laboratory and the clinical acumen of the personnel. A magnetoencephalography report is not meant to enumerate all the technical details that went into the test nor to fulfill some imagined requirements of the electronic health record. It is meant to clearly and concisely answer the clinical question posed by the referring doctor and to convey the key findings that may inform the next step in the patient's care. The graphical component of a magnetoencephalography report is ordinarily the most welcomed by the referring doctor. Much of the text of the report may be glossed over, so the illustrations must be sufficiently annotated to provide clear and unambiguous findings. The particular images chosen for the report will be a function of the analysis software but should be selected and edited for maximum clarity. There should be a composite pictorial summary slide at the beginning or at the end of the report, which accurately conveys the gist of the report. Along with representative source localizations, reports should contain examples of the simultaneously recorded EEG that enable the referring physician to determine whether epileptic discharges occurred and whether they are consistent with the patient's previously recorded spikes. Information and images (e.g., statistics, magnetic field patterns) that provide convincing evidence of the validity of the source location should also be included.


Asunto(s)
Encéfalo/fisiopatología , Electroencefalografía/métodos , Epilepsia/fisiopatología , Magnetoencefalografía/métodos , Proyectos de Investigación , Encéfalo/diagnóstico por imagen , Electroencefalografía/normas , Epilepsia/diagnóstico por imagen , Humanos , Magnetoencefalografía/normas , Proyectos de Investigación/normas , Programas Informáticos/normas
20.
J Clin Neurophysiol ; 37(6): 554-563, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33165228

RESUMEN

Numerous studies have shown that language processing is not limited to a few brain areas. Visual or auditory stimuli activate corresponding cortical areas, then memory identifies the word or image, Wernicke's and Broca's areas support the processing for either reading/listening or speaking and many areas of the brain are recruited. Determining how a normal person processes language helps clinicians and scientist to understand how brain pathologies such as tumor or stroke can affect changes in language processing. Patients with epilepsy may develop atypical language organization. Over time, the chronic nature of epileptic activity, or changes from a tumor or stroke, can result in a shift of language processing area from the left to the right hemisphere, or re-routing of language pathways from traditional to non-traditional areas within the dominant left hemisphere. It is important to determine where these language areas are prior to brain surgery. MEG evoked responses reflecting cerebral activation of receptive and expressive language processing can be localized using several different techniques: Single equivalent current dipole, current distribution techniques or beamformer techniques. Over the past 20 years there have been at least 25 validated MEG studies that indicate MEG can be used to determine the dominant hemisphere for language processing. The use of MEG neuroimaging techniques is needed to reliably predict altered language networks in patients and to provide identification of language eloquent cortices for localization and lateralization necessary for clinical care.


Asunto(s)
Investigación Biomédica/normas , Mapeo Encefálico/normas , Encéfalo/fisiología , Lenguaje , Magnetoencefalografía/normas , Guías de Práctica Clínica como Asunto/normas , Investigación Biomédica/tendencias , Encéfalo/diagnóstico por imagen , Mapeo Encefálico/tendencias , Epilepsia/diagnóstico por imagen , Epilepsia/fisiopatología , Humanos , Magnetoencefalografía/tendencias , Neuroimagen/métodos , Neuroimagen/tendencias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...